using System;
using System.Collections.Generic;
using System.ComponentModel;
using System.Data;
using System.Drawing;
using System.Linq;
using System.Text;
using System.Threading.Tasks;
using System.Windows.Forms;
using System.Threading;
namespace HTOLHAST
{
public partial class Form1 : Form
{
HMP4040 PSU1;
HMP4040 PSU2;
Keithley6485 PAM;
Agilent34970a DAQ;
public Form1()
{
InitializeComponent();
}
public void InitializeInstruments()
{
// Mandatory instruments:
InitializePSU1(tbResourceStringPSU1.Text);
InitializeDAQ(tbResourceStringDAQ.Text);
// Optional Instruments check if to be used
if (cbPSU1Enabled.Checked)
{
InitializePSU2(tbResourceStringPSU2.Text);
}
if (cbPAMEnabled.Checked)
{
InitializePAM(tbResourceStringPAM.Text);
}
}
public void InitializePSU1(string resourceString)
{
try
{
PSU1 = new HMP4040(resourceString);
}
catch (Exception)
{
throw;
}
}
public void InitializePSU2(string resourceString)
{
try
{
PSU2 = new HMP4040(resourceString);
}
catch (Exception)
{
throw;
}
}
public void InitializePAM(string resourceString)
{
try
{
PAM = new Keithley6485(resourceString);
}
catch (Exception)
{
throw;
}
}
public void InitializeDAQ(string resourceString)
{
try
{
DAQ = new Agilent34970a(resourceString);
}
catch (Exception)
{
throw;
}
}
public void HamegValidationOfMethods()
{
string resourceString = "ASRL4::INSTR"; // Replace with your instrument's resource string
HMP4040 hameg = new HMP4040(resourceString);
hameg.GetID();
string voltageResponse = hameg.MeasureVolt(1);
Console.WriteLine($"Measured Voltage: {voltageResponse} V");
string currentResponse = hameg.MeasureCurrent(1);
Console.WriteLine($"Measured Current: {currentResponse} A");
string voltageSetpoint = hameg.SetVoltage(1.1, 1);
Console.WriteLine($"Voltage Setpoint: {currentResponse} V");
string currentSetpoint = hameg.SetCurrent(0.1, 1);
Console.WriteLine($"Current Setpoint: {currentResponse} A");
hameg.PowerUpSequence(hameg.GenerateSimulationPowerUpSequence());
hameg.PowerDownSequence(hameg.GenerateSimulationPowerUpSequence());
}
public void KeithleyValidationOfMethods()
{
// Example usage
string resourceString = "ASRL3::INSTR"; // Replace with your instrument's resource string
Keithley6485 keithley = new Keithley6485(resourceString);
// Query the instrument ID
keithley.Reset();
string idnResponse = keithley.GetID();
Console.WriteLine($"Instrument ID: {idnResponse}");
// Measure DC current
keithley.PerformZeroCheck();
string currentResponse = keithley.MeasureDCCurrent();
Console.WriteLine($"Measured Current: {currentResponse}");
// Close the instrument connection
keithley.Close();
}
private void btnInitializeInstruments_Click(object sender, EventArgs e)
{
InitializeInstruments();
}
}
}